Multifunction Instrument for Electrical Measurements with Oscilloscope

Mod : FT- mim023

Welcome to our comprehensive Trainer Catalogue, designed to enhance your learning and experimentation in electrical and electronics engineering. This catalogue features a versatile trainer equipped with various power supply options, load types, and measurement instruments, allowing for a wide range of practical experiments. Whether you are exploring AC and DC power supplies, analyzing resistive and inductive loads, or measuring power consumption and efficiency, our trainer provides the tools and flexibility needed for in-depth study and hands-on learning. Dive into our carefully curated experiments and unlock a deeper understanding of electrical systems and their behaviors.

Description

Multifunction Instrument for Electrical Measurements with
Oscilloscope

Technical Specification :

Showing electrical wiring tips on the LCD screen
User-defined backlight setting (10/20/30 sec.)±0.2% precision
Fast and accurate response rate
Effective measurement of RMS values
Indication of a measured data in the minimum, maximum and average values
Earth resistance measurement in two points and three points
Automatic Power OFF function
Bluetooth communication
Should Display the connection of reed wires
AUTO/MANUAL range selection
Initiation of calibration by pressing a key button
ACV: 0.0-750.0V True RMS
DCV: 0.0-999.9V
Insulation resistance (MEG Ω):
DC 1000V: 0.00MΩ ~ 9.99MΩ, 10.00MΩ ~ 99.99MΩ, 100.0MΩ ~1999MΩ
DC 500V: 0.00MΩ ~ 9.99MΩ, 10.00MΩ ~ 99.99MΩ, 100.0MΩ ~ 999.9MΩ
DC 250V: 0.00MΩ ~ 9.99MΩ, 10.00MΩ ~ 99.99MΩ, 100.0MΩ ~ 999.9MΩ
Ground resistance (EAR Ω): 0 ~ 2000Ω
Ground voltage (EV): 0.0 ~ 750.0V AC, True RM
PHA: AC110V-750V LCD Display
HOT: AC70V-750V Buzzer, LCD Display
ACA: 0 ~ 9999A, True RMS
Ior: 0.00 ~ 9.99mA, True RMS
Communication: Bluetooth 4.0
Standard Accessories:
User’s guide manual
1.5V Alkaline AA battery – 5ea
Protective rubber cover (orange color)
Carrying bag – 1ea
Test lead wire (red color, mega Ω and 1.2m roll length) – 1ea
Test lead wire (black color, mega Ω and 1.2m roll length) – 1ea
Test probe (red color, 600V and CAT III) – 1ea
Test probe (black color, 600V and CAT III) – 1ea
Crocodile clip (black color, EN61010 and CAT III) – 1ea
Test lead wire (green color, KSC3325 and 1.2m roll length) – 1ea
Test lead wire (red color, 600V and 20m roll length) – 1ea
Test lead wire (yellow color, 600V and 10m roll length) – 1ea
Test lead wire (green color, 600V and 5m roll length) – 1ea
Ground rod – 2ea
Oscilloscope Specifications:
Min. 100 MHz bandwidth, 2-channel
Min. 1 GS/s sample rate on all channels
Min. 20k point record length on all channels
Advanced triggers include pulse, runt, and line triggers
Min. 7-inch WVGA color display with 15 horizontal divisions that shows
50% more signal
32 automated measurements
Dual window FFT with simultaneous time and frequency domain views
Trigger frequency counter
Pan and Zoom capability
Multi-language user interface with support for 10 languages in the user
interface and front panel overlay
Vertical resolution: 8 bits
Input sensitivity range: 1 mV/div to 10 V/div max, in 1-2-5 sequence with
probe attenuation set to 1X
DC gain accuracy: ±3.0 % step gain, derated at 0.1 %/°C above 30 °C

Maximum Input Voltage: 300 VRMS, Installation Category II; derate above 4 MHz at 20 dB per
decade to 200 MHz
Offset range: 1 mV/div to 50 mV/div: ± 1 V, 100 mV/div to 500 mV/div: ± 1 V
1 V/div to 5 V/div: ± 100 V
Bandwidth limit: 20 MHz (Typ)
Input coupling: DC, AC
Input impedance: 1 MΩ ±2 % in parallel with 14 pF ±2 pF
Vertical zoom: Vertically expand or compress a live or stopped waveform
Peak Detect: Captures glitches as narrow as 4 nsec at all sweep speeds.
Average: From 2 to 256 waveforms included in average.
Hi-Resolution: Averages multiple samples of one acquisition interval into one waveform point.
Roll: Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40
ms/div
Time base accuracy: ±25 x 10
66 over any >1 ms interval
Time base range: 2 ns/div to 100 sec/div in a 1-2-4 sequence
Horizontal zoom: Horizontally expand or compress a live or stopped waveform
Deskew range: ± 100 nsec
Trigger modes: Auto, Normal, Single Sequence
Trigger source: CH1, CH2, AUX IN, AC Line
Trigger Coupling: DC, Noise Reject, High Frequency Reject, Low Frequency Reject
Automated measurements: 32, of which up to six can be displayed on-screen at any one time.
Measurements include: Period, Frequency, Rise Time, Fall Time, Positive Duty Cycle, Negative
Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive
Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle
Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count,
Falling Edge Count, Area, Cycle Area, Delay FR, Delay FF, Delay FR, and Delay RR.
Display Resolution: 800 horizontals by 480 vertical displayed pixels (WVGA)
Waveform styles: Vectors, Variable persistence, and Infinite persistence.

Accessories : 
Standard accessories.
User manual: 1 Nos.
Connecting Wire: 1 set

Others :
Origin Parts : China, Taiwan, Japan.
Manufacturing in Bangladesh.
Warranty: 01 year.
Installation, Testing.
Training.

Related Products