Biomedical Measurement Training System

MOd : FT – BMT230

The Bio-Medical Measurement System Trainer is a comprehensive platform designed for studying and analyzing vital physiological parameters. It facilitates hands-on learning with modules for Electrocardiogram (ECG), Electromyogram (EMG), Electrooculogram (EOG), blood pressure, photo plethysmogram, respiratory monitoring, ventilation detection, pulse measurement, and body impedance detection. This trainer integrates advanced measurement systems, modular experiment panels, and PC interfacing capabilities. It is ideal for exploring bio-medical signal acquisition, analysis, and applications in healthcare, providing students with practical experience in medical electronics and instrumentation.

Description

Biomedical Measurement Training System

Technical Specification :

Main Unit:1. Function Generator
-Output Waveform: Sine, Squareand Triangle Frequency Range:
0.01Hz to 1MHz, continuouslyadjustable
-Amplitude Range: 50mVpp to18Vpp (open circuit)
-DC Offset:
– 10V to +10V
-Display: 4-digit, 7-segment display
Interface
-Port USB Interface: Type B
Input Indicators IN1, IN2, IN3, IN4, IN5 LEDs, indicating thecorre-
sponding connection for students when conductingexperiments of

ECG, EMG, EOG, EEG and body impedance.
Reset Switch for MCU reset
Select Switch for selection of themodules
LCD Status Display
-Display the output frequency ofthe function generator
-Display the module selected
-Display Heart Rates, Respiration,Pulse Rates and Doppler
Ultrasound Blood
BNC Adaptor Connector for 2mm sockets BNC sockets 8.Module
Output DB9 connector
List of Module:
Module-1:Electrocardiogram ECG Module
-Limb lead inputs
-Limb electrode-6 limb leads: Lead I, Lead II, Lead III, aV , aV , aV
0-Isolationcircuit -Gain: 100~5000
-Band-pass filter: 0.1to100Hz
-1 outputECG signal Module
-2: Electromyogram EMG
Module -Surfaceelectrode
-Gain: x 1000, x 2000
-Isolation circuit
-Band-pass filter: 100 to1000Hz
-2 outputs:Electromyogram signal and Muscle force signal 2
Module -3:Electrooculogram EOG Module -Surface electrode
-Gain: 5to3000-Isolation circuit -Band-pass filter: 0.05to30Hz
-2 outputs:Horizontal signal, Vertical signal
Module-4: ElectroencephalogramEEG Module
-EEG electrode -Gain: 5 to5000
-Isolation circuit
-Band-pass filter: 1~20Hz
-1 output EEG signal
Module-5: BloodPressure Measurement Module
-Pressure transducer:
–Differential pressure model
–Pressurerange: 0~5 psid
–Accuracy: 0.5 percentage
–Input impedance :5K -Pressure calibration circuit
-Gain amplifier : 20~800
-Band-pass filter : 0.3~3Hz
-2 outputs: Cuff pressure signal,Oscillometric pulse signal  
Module-6: Photoplethysmogram Module 
      
-Infrared light 
-emitting diode  
–Rated forward current IF = 60mA  
–Rated reverse voltage VR = 4V 
–Peak wavelength λp = 880nm 
–Δθ = ± 53deg  
-Phototransistor  
-Rated C-E voltage VCEO = 20V  
-Rated collector power Pc =75mW  
-Peak wavelength λp = 800nm d. Δθ = 50deg. 
-Gain: x 50~500, x 100~1000  
-Band-pass filter: 0.3 to40Hz 
Accessories : 
Standard accessories.
User manual: 1 Nos.
Connecting Wire: 1 set

Others :
Origin Parts : China, Taiwan, Japan.
Manufacturing in Bangladesh.
Warranty: 01 year.
Installation, Testing.
Training.

Related Products