Electrical Wiring Trainer Board (component & sequence)

MOd : FT – ED111

The Electrical Wiring Trainer Board is a comprehensive educational tool designed to provide hands-on experience in electrical wiring and circuit management. Operating at 220V AC, this robust trainer features a variety of components, including push-button doorbell switches, pilot lights, duplex receptacles, lamp sockets, and a standard residential circuit breaker panel. Its practical layout facilitates a deeper understanding of electrical systems, safety, and functionality. With dimensions of 31″ L x 36″ W x 25″ H, it offers a user-friendly interface for both students and educators, making it an ideal resource for electrical training and experimentation.

Description

Electrical Wiring Trainer Board
(component & sequence)

Technical Specification :

Electrical Training System:
Provide available electrical components and interconnect in different
configurations.
Acquire the basic knowledge on electrical engineering, installations
and electrical measurements.
Study the means to check the main laws and principles.
Component symbols and electrical diagrams are represented on the
front panel.
The symbols and electrical diagrams of each component are clearly
represented on the front panel.
The connections are eased by 4mm terminals and cables of different
colors.
The power supplies are included with extra low safety voltage.
General switch, fuse and signaling lamp:
1 Safety single-phase transformer 115-230V/ 6-12-24 VAC-1 A
2 Fuse-holder with fuse type 6×30-1A
1 Moving iron ammeter with range: 0.5-1A
1 Moving iron voltmeter with range: 25 V
10 Resistors of different values (2, 4, 8, 16, 31.5, 63, 250, 500, 1000,
2000)
1 linear rheostat 100/25W
4 Diodes 6A-100V
2 Lamp-holder with 24-V signaling lamp
1 24-Vac buzzer
1 Electrolytic capacitor, 100 F25Vdc
2 Electrolytic capacitors, 500 F25Vdc
2 Inductances 60 mH 0.5 A
Electrical Sequence Trainer:
Hands-on electrical sequence practices using various electrical
components with electric contact.
Simulates real life components and power source that is being used in
the field
Ensures safety using insulated connection cables and insulated
connection terminals
Experimental Contents:
Basic circuit
Logic circuit
Self-holding circuit
Timer circuit
Priority circuit
Detection circuit
Lamp and alarm circuit
Motor operational circuit
Reactor-driving circuit
Jog circuit
Forward & reverse circuit

Delay operation circuit
Time activation circuit
Y-Δ operational circuit
Earth leakage circuit breaker (ELCB): 1 ea
Rated voltage: AC 220V 60Hz
Rated current: 30A
Rated residual current: 30mA
Electronic contactor (5a2b): 3ea
Contact capacity: AC 240V/18A / 4.5kW
Auxiliary contact capacity: AC 240V 3A
Electronic overload relay (EOCR, 1/2HP): 1 ea
Internal CT (sensor): 3-CT (tunnel type)
Current setting: 0.3 ~ 1.5A
Trip time setting: 0 ~ 30 sec.
Contact capacity: AC 250V 3A (Resistive load)
Relay (4C): 2ea
Contact capacity: AC 220V 3A (Resistive load)
Timer (30 seconds): 1ea
Operational method: ON delay
Output contact capacity: AC 220V 1.5A (Resistive load)
Flicker timer (6 seconds): 1ea
Operational method: ON Start
Output contact capacity: AC 220V 2.5A (Resistive load)
3-phase induction motor: 1ea
Operating voltage: 3-phase AC 220V / 380V / 25W
Type of motor: Squirrel cage rotor, 4-pole and Y-Δ Starting
Rotary disc: Rotational speed detection type
Electronic brake: Intensity control function
Proximity sensor: 1ea
Digital counter: 1ea
DC power supply: 1ea Output: DC 24V 1A (fuse)
Lamp: 4ea
Buzzer: 1 ea
Push button: 4ea
Toggle switch (1a1b): 2ea
Fuse and fuse holder: 2ea
Supports angle adjustment: 1ea
STANDARD ACCESSORIES:
Power cord: 1ea
4ø insulated connection cable: 1set
User’s guide & experimental manual: 1ea
Digital Multifunctional Meter:
Showing electrical wiring tips on the LCD screen
User-defined backlight setting (10/20/30 sec.)
±0.2% precision
Fast and accurate response rate
Effective measurement of RMS values
Indication of a measured data in the minimum, maximum and average
values
Earth resistance measurement in two points and three points
Automatic Power OFF function

Bluetooth communication
Displays the connection of reed wires
AUTO/MANUAL range selection
Initiation of calibration by pressing a key button
ACV: 0.0-750.0V True RMS
DCV: 0.0-999.9V
Insulation resistance (MEG Ω):
DC 1000V : 0.00MΩ ~ 9.99MΩ, 10.00MΩ ~ 99.99MΩ, 100.0MΩ ~
1999MΩ
DC 500V : 0.00MΩ ~ 9.99MΩ, 10.00MΩ ~ 99.99MΩ, 100.0MΩ ~
999.9MΩ
DC 250V : 0.00MΩ ~ 9.99MΩ, 10.00MΩ ~ 99.99MΩ, 100.0MΩ ~
999.9MΩ
Ground resistance(EAR Ω): 0 – 2000Ω
Ground voltage(EV): 0.0 ~ 750.0V AC, True RM
PHA: AC110V-750V LCD Display
HOT: AC70V-750V Buzzer, LCD Display
ACA: 0 ~ 9999A, True RMS
Ior: 0.00 ~ 9.99mA, True RMS
Communication: Bluetooth 4.0

 

Accessories : 
User’s guide manual
1.5V Alkaline AA battery – 5ea
Protective rubber cover (orange color)
Carrying bag – 1ea
Test lead wire (red color, mega Ω and 1.2m roll length) – 1ea
Test lead wire (black color, mega Ω and 1.2m roll length) – 1ea
Test probe (red color, 600V and CAT III) – 1ea
Test probe (black color, 600V and CAT III) – 1ea
Crocodile clip (black color, EN61010 and CAT III) – 1ea
Test lead wire(green color, KSC3325and 1.2m roll length) – 1ea
Test lead wire (red color, 600V and 20m roll length) – 1ea
Test lead wire (yellow color, 600V and 10m roll length) – 1ea
Test lead wire (green color, 600V and 5m roll length) – 1ea
Ground rod – 2ea

Others :
Origin Parts : China, Taiwan, Japan.
Manufacturing in Bangladesh.
Warranty: 01 year.
Installation, Testing.
Training.

Related Products