Description
Switchgear and Protection Trainer
Technical Specification (Category – 1):
Show skill in connecting cutout, MCB/MCCB in a circuit.
Test the rating of circuit breaker(6A, 10A),
Demonstrate poly-phase system and phase sequence.
Show skill in connecting Phase Fault Relay,
Show skill in phase missing test,
Show skill in Over voltage test,
Show skill in Under voltage test,
Show skill in phase sequence test,
Perform star-delta conversion in a power system.
Study the different parts of a energy meter.
Study the different parts of a Busbar, Thermal over load relay,
Magnetic contact, Timer etc.
Measure the energy of a three phase circuit by three phase
energy meter.
Perform the identification of the parts of a three phase induction motor.
Start a 3-phase induction motor by star-delta starter using
magnetic contactor switch.
Start a 3-phase induction motor by Auto star-delta starter
using Timer & magnetic contactor switch.
Categorize different types of fuses and measure the current
carrying capacity of HRC fuse.
Specification:
Three Phase AC/DC Power Supply:
Rated Input Voltage: 400 V AC(±5%) Three Phase 4-wire
Rated Output Voltage: 400 V AC (±5%) Three Phase 4-wire,
Rated Output Voltage:0~ 400 V AC (±5%) ,Three Phase
4-wire, Rated Output Current: 5 AC (±5%) ,
Rated Output Voltage: 120 V DC (±5%) ,5Amp
Rated Output Voltage:0~ 220 V DC (±5%) ,5Amp, Short
CircuitProtection Facility
4mm safety jack Connection facility, Air Cooling system
facility
Control Board:
Three Phase Energy Meter: 1 EA, BAS Bar :4EA, Circuit
Breaker :3EA(10Amp), Cartridge Fuse:3EA (10Amp),
HRC Fuse: 3EA (15Amp),Thermal Overload Relay: 1 E,
Phase fault Relay: 1EA
Digital Timer: 2EA, Magnetic Contractor: 3EA, Selector
Switch:2 EA,Rated Input Voltage: 400 V AC (±5%) ,50Hz
Three Phase 4-wire
1 Training Manual,4mm safety banana socket, Size (L x
W x H)= (60?x36?x12?), Weight:100Kg (Approx), Power
requirements: 220~240V AC, 50Hz, Built-inshort circuit
protection system.
Specification: (2)
Auto re-closer (Electromechanical)
1-Φ, 230V, 2 Amp, 50 Hz, Reclosing Duration 5-180 Seconds adjustable,
Reclose times 2-10 Adjustable.
Under voltage / over voltage protection relay
Excitation voltage: 180-240 volt
Input voltage (Under/over range): 160?280VAdjustable, Current handling
capacity: 0-5 Amp
Frequency: 45-60 Hz.
Under current / over current protection relay with autore-closure
Excitation voltage: 180-240 volt
Under current / over current range: 0-5 AmpAdjustable, Voltage handling
capacity: – – 160-280Volt
Frequency: 45-60 Hz.
Under frequency / over frequency protection relay
Excitation voltage: 180-240 volt
Under frequency / over frequency range: 35-60 HzAdjustable, Voltage handling
Capacity: 160-280 Volt
Current handling capacity: 0-5 Amp.
Reverse Phase Sequence Protection Module
3- Φ, 400-440V volt, 3 Amp, 50 Hz.
Transformer over heat Protection Module
Excitation voltage: 180-240 volt, 1-Φ, 230V,Temperature 10°C-100°C,10
Amp, 50 Hz.
Auto Y-Δ Starter
3- Φ, 400-440V volt, 5 Amp, 50 Hz.
Squirrel Cage Induction Motor
400V, 0.7A, 3Φ, 50 Hz, 190W (Min), 1380 rpm.Copper conductor, SS shaft,
Aluminum yoke,
All terminals are on front plate.
Use for educational experiment purpose.
DC Motor/ Generator
Motor Rating: 200V DC, 1.5A, 200W (Min), 1500rpm Shunt field rheostat (for
speed control).
– Generator Rating: 150V DC, 0.75A, Shunt fieldrheostat (for voltage control)
Prime mover speed 1500 rpm.
– Copper conductor, SS shaft, all terminals are onfront plate.
– Use for educational experiment purpose.
Synchronous Motor/Generator
DC Excitation in rotor circuit winding type: Lapwinding, single layer. Motor
Rating: 3 Phase, 415V,0.5A-1.5A, 190W (Min), 50 Hz, 1500 rpm, GeneratorRating: 3 Phase, 415Volt, 200VA (Min), 0.25A-1.5A,50Hz, 1500 rpm.
Copper conductor, SS shaft, Aluminum yoke,
All terminals are on front plate.
Use for educational experiment purpose.
Power Supply
AC 3 Phase, 4 Wire, 440Volt (Max), 230 Volt 10A,Variable 0-440Volt, 4Amp,
DC: 240Volt (Max), 10A(Max), Variable 0-240Volt, 5Amp,
All terminals are on front plate, Use for educational experiment purpose.
Mobile Consol (Work Station)
Dimension:
Wheel mounted, one double size, four full size,three half size module cabinet, one
door cabinet with lock, Auto release & sliding tray, Use for educational
experiment purpose.
Connecting Cables-Cable length 01 yds. With both & Staking plugs -50 pcs.
Safety & Security: Over voltage, over current andearth fault protection
Accessories:
●Connecting Wire: 1 set
●User Manual: 1 Nos
●Standard Accessories
Others:
●Country of Origin: China
●Manufacturing: Assemble in Bangladesh
●Training
Reviews
There are no reviews yet.